The application of these tests proved to be very useful in several ways: a) revealed algorithmic errors which were fixed, b) revealed algorithmic shortcomings which were improved or eliminated through the use of more rigorous calculations for certain components, and c) caught newly introduced bugs before public release of updates. Type190 now limits the voltage until both voltage and power are under the limit. Each of these HVAC BESTEST series were used to test EnergyPlus prior to new public releases. Bugfix: Type190 set the output power to zero if the PV array power and voltage were both above the inverter’s voltage and power limits. TRNSYS is a commercial software package developed at the University of Wisconsin. The second is a series of analytical/semianalytical comparative tests for a single-zone fuel-fired furnace which tests a program's ability to model steady state performance, varying outdoor and indoor conditions, and circulating and draft fan operation. TRNSYS is a simulation program primarily used in the fields of renewable energy engineering and building simulation for passive as well as active solar design. The first is a series of comparative tests for a single-zone DX cooling system which tests a program's ability to model hourly loads over an expanded range of performance conditions for various air mixing, infiltration, thermostat set-up, overload conditions, and various economizer control schemes. The EnergyPlus building energy simulation software has been tested using the IEA HVAC BESTEST E300-E545 series of tests and the IEA HVAC BESTEST Fuel-Fired test series.